What Size Wire For 200 Amp Service Underground

When installing a 200 amp electrical service, you demand to exist sure you lot use the right judge wire. You'll need a permit to practice the professional installation. Many areas however allow homeowners to obtain their permits. You'll need to cheque with your local building department to know if yous can become the permit or if you'll demand the help of an electrician.

Installation of 200 amp electrical service needs a #ii/0 AWG copper wire or #4/0 AWG for aluminum or copper-clad wire within a minimum of 1.v inches, schedule xl or lxxx PVC conduit for clandestine service. However, 2 or 2.five inches is recommended if running iii wires in the same conduit.

Wiring 200 amp service requires an electric permit and professional installation by a qualified electrician in accordance with local electric codes.

Power is received from the utility service lines and flows through the outside electrical meter base and into the main electrical panel in an attached garage, basement, or interior room.

Wire Sizes for 200 Amp Service

AWG, American Wire Approximate, is the U.s.a. standard for sizing electrical wiring.

Wiring a 200 amp feeder requires either #2/0 copper wiring or #4/0 aluminum or copper-clad wiring. Which wire is used is adamant by the voltage drib and length of the wiring.

The following tabular array reflects wiring size, length, and voltage drop:

Service or Feeder Rating Copper Wire Aluminum or
Copper-Clad Aluminum Wire
Minimum Conduit Size
100 Amps #4 AWG #ii AWG 1.25 inch
110 Amps #3 AWG #1 AWG 1.25 inch
125 Amps #2 AWG #1/0 AWG 1.25 inch
150 Amps #1 AWG #two/0 AWG i.25 inch
175 Amps #1/0 AWG #3/0 AWG ane.five inch
200 Amps #2/0 AWG #4/0 AWG 1.five inch
225 Amps #3/0 AWG 250 kcmil ane.5 inch
250 Amps #4/0 AWG 300 kcmil 2 inch
300 Amps 250 kcmil 350 kcmil 2.5 inch
350 Amps 350 kcmil 500 kcmil three inch
400 Amps 400 kcmil 600 kcmil iii inch
Source: National Electric Code

Many electrical contractors opt to use #4/0 aluminum or copper-clad wire.

For copper conductors, you'll need a #2/0 AWG copper wire commonly used for electric wiring because information technology is more rut resistant than aluminum. Copper won't rust and is resistant to oxidation.

For aluminum or copper-clad aluminum wiring, you'll need #4/0 AWG aluminum wiring. Aluminum wiring requires a larger diameter wire because it has a lower conductivity than copper. Aluminum wiring requires an antioxidant coating at the connection terminals to resist corrosion. Copper-clad aluminum doesn't require an antioxidant coating at the connection terminals.

Aluminum wirings appeal widespread because it costs less, is lightweight, and is more flexible than copper, even though copper is considered a amend usher.

Why Copper Wiring is Preferred over Aluminum

Electricians and homeowners alike prefer copper wiring, peculiarly for branch circuits. Copper wiring has many benefits, including:

  • Conductivity: Copper wire is a highly conductive metal, 2d only to argent. Copper can handle a higher electrical load, and so you can use a smaller gauge wire. In fact, copper wire is almost half the diameter of aluminum wire for the same conductivity.
  • Heat Resistant: Copper wire conductive properties make the wire more estrus resistant than aluminum wire. Copper wire does non expand and contract like aluminum which means the wire connections remain tight on lugs.
  • Corrosion Resistant: Copper is resistant to corrosion. Patina is a greenish-tarnish that changes the outer color of copper. Patina forms by oxidation, notwithstanding, do not impact the electrical conductivity.
  • Malleability: Because copper is highly conductive, the wire strands are thinner, making the wire more malleable without the risk of breaking.
  • Distance: Copper conductors tin can be used over longer distances due to its highly conductive properties and heat resistance.

Pros of Aluminum or Copper-Clad Aluminum Wire

We but discussed why copper is preferred; withal, copper-clad and aluminum wire sizes are more pop on service entry wire for several reasons, including:

  • Budget-Friendly: Aluminum wire is preferred due to its lower cost. Aluminum conductors are cheaper to produce compared to copper conductors. Aluminum copper-clad is better merely does cost more than than aluminum wiring. Aluminum costs much less than copper-clad and copper wires.
  • Faster Installation: Aluminum is lighter than copper and very malleable for its larger wire gauge. Electricians find is easy to piece of work because is lightweight and feeds well through the electrical conduit which makes for faster installation and lowers material and labor costs.

Aluminum wiring expands and contracts with heat which causes the wire connection to loosen over fourth dimension, raising the risk of an electrical fire. Aluminum service wiring is a grouping of smaller solid aluminum strands rather than ane solid wire, making the aluminum wire condom to use in residential homes.

The Length Your Service Wire Runs Matters

When calculating wire size, you need to know how far the service archway wires will run from the electric meter base to the electrical panel. The maximum voltage driblet (we volition talk over presently) immune is 3%. The distance your service entry wire needs to travel will determine whether you use aluminum or copper wire and gauge necessary.

Service Wire Size Maximum Altitude
Copper #2/0 Wire 50 feet
Copper #3/0 Wire 100 feet
Copper #4/0 Wire 150 feet
Aluminum #4/0 Wire fifty feet
Aluminum 300 kcmil 100 anxiety
Distances may vary past location. Check with your local building section for requirements.

You tin can use aluminum and copper for a 200 amp service entry wire. Even so, the aluminum guess will exist higher due to its reduced electrical conductivity and estrus resistance properties. You lot can apply copper wire over a longer distance.

What is Voltage Drop?

Voltage drib is the loss of voltage that occurs over the wire due to natural resistance. The longer a wire runs, the more than voltage loss that occurs. The size wire gauge has to increase to offset the voltage driblet.

The voltage at the excursion breaker should exist 120 volts. Using a voltage meter, take a reading at the appliance or the farthest device. Ideally, you should not have a voltage drop higher than 3%. For a 120-volt electric circuit, the voltage drop should be no less than 117 volts. Likewise, on 233 volts on a 240-volt electrical circuit.

How Many Wires You Need for 200 amp Service

The type of wire y'all need will vary depending on your electrical system. The run from the meter base to the primary disconnect box or main panel is 3-wire, consisting of ii hot wires and i neutral wire. The neural and ground bars have electrical bonding connecting the confined.

The feeder run from the primary electrical panel to the interior distribution panel (subpanel) is 4-wire, consisting of ii hot wires, one neutral wire, and one ground wire. You don't bond the neutral and ground bars inside subpanels.

What Size Conduit You Need for 200 Amp Service

An electrical panel has knockouts for connecting electrical feeder conduit. Y'all tin can use either a 2-inch or 2.5-inch conduit based on the fill space yous intend to occupy inside the conduit. If 3 or more wires are inside the conduit, the maximum fill infinite of 40%.

In Chapter 9, Table 5A of the 2017 NEC, a #4/0 Aluminum stranded conductor takes upward 176.3mm2 of fill space. If you lot multiply 176.3mm2 by 4 gives you lot a total of 705.2mm2 of fill space used past the entire feeder.

Co-ordinate to Chapter 9, Table four of the 2017 NEC, a 2″, Schedule 80 PVC conduit has 742mm2 usable fill.

And so, a 2″ conduit volition suffice, or you can upsize to two.5″ if y'all wish for ease of pulling. Keep in mind that the expanse of the wires must be less than 40% of the internal space of the pipe when 3 or more than wires are present.

What Size Ground Wire for 200 Amp Service

The NEC is the electrical code used in the United States. The minimum size for a grounding wire for 200 amp is #4 AWG copper or #2 AWG aluminum, according to Article 250 of the 2020 NEC.

The size of the primary conductor may demand to increase for a diversity of reasons, including the length of the run, bachelor fault current, or any number of reasons. The NEC is a prophylactic guide. Local municipalities set and adopt code guidelines. Call a local electrician or your metropolis for specific guidelines.

GROUNDING ELECTRODE CONDUCTOR SIZING (Table 250.66)

Size of Main Console Copper Conductors Aluminum or Copper-Clad Aluminum
125 Amps #8 AWG #6 AWG
150 Amps #6 AWG #4 AWG
200 Amps #4 AWG #2 AWG

What Size Ground Rod for 200 Amp Service

A ground rod needs to be at least 5/8″ (0.625) in diameter and at least eight to 10 feet long with a clamp and the appropriate ground wire. The basis rod needs to be driven 8 anxiety deep into the basis and cut back close to the ground. The wire and clamp are secured tightly to the top of the ground rod.

Where in that location is a lot of electricity in the basis, a thicker #iii size wire may be required. Two basis rods are necessary for regions where soil electrical resistance is high because of new code requirements.

Use the right type of grounding rod. Pipe or rebar can also be used for grounding. The grounding rod must be galvanized steel and should exist at least viii feet long.

How Many Ground Rods for 200 Amp Service

A ground rod that does non meet the NEC's 25 OHMS or less requirement necessitates using a second ground rod, with the basis rods existence at least half-dozen′ autonomously.

You install a ground rod for a system, and the first ground rod has a resistance of 25 ohms or more. According to the NEC, you must install a second grounding rod. On the other manus, many contractors do non accept basis resistance into account. They conceptualize driving ii footing rods to satisfy 250.56'due south standards regardless of actual ground resistance. Equally a consequence, ii ground rod connections are typical but aren't ever necessary.

The NEC article 250.53(B) requires you to space grounding rods at to the lowest degree 6 feet apart connecting past a grounding wire. Yet, this spacing is a minimum. When using the typical 8-foot or x-human foot basis rod, y'all get the best results past spacing them at to the lowest degree 16 or xx feet apart, much farther than the minimum 6-pes spacing.

Check Local Electrical Codes & Permit Requirements

Electric codes are set past the National Electrical Code (NEC) but can vary by location. Using a qualified electrician ensures your 200 amp electric service meets local codes and permit requirements.

The 200 amp size wire referred to in this article is from the NEC code and may vary from your local building code. Your local lawmaking will prefer or alter the NEC codes to fit their requirements.

Before the utility service can connect power to the business firm, you'll demand a Certificate of Occupancy (CO). The let allows for a final inspection to connect the electric service. The CO is issued later on the electrical work has passed the building inspection.

200 Amp Electrical Service Installation Costs

It's nearly impossible to accurately cost the cost of installing a 200 amp entry service in a house. We need to consider numerous factors, like location, the corporeality of work required, and material costs in your area. Installing a 200 amp electrical service typically includes installing a 200 amp service wire, conduit, meter base of operations, and a 200 amp electrical panel.

Based on HomeAdvisor.com, the national boilerplate toll of a complete 200 amp electrical installation costs $1,900 to $vii,250, with boilerplate costs of $4,650, includes the following:

  • 200 Amp Service Console: Boilerplate toll ranges from $750 to $2000, with a median cost of $1375.
  • 200 Amp Meter Base: Average cost ranges from $150 to $400, with a median price of $275.
  • 200 Amp Service Wire: Average toll ranges from $1000 to $5,000, with a median cost of $3,000.

According to MidPenn Electrical, a leading electrical contractor in Pennsylvania, "a new 200 amp service can cost anywhere from $4,200 to $five,000". Therefore, the HomeAdvisor cost averages seem to exist reasonably accurate.

Decision

Installing 200 amp wire is not a DIY projection for homeowners. Wiring a 200 amp console is a big project that requires the services of a qualified and certified electrician. Y'all may require a permit to install a 200 amp service. The electric service will demand to be disconnected entirely in existing homes to install the 200 amp service.

Also, see our guide, Wire Size for 100 Amp Electrical Service.

What Size Wire For 200 Amp Service Underground,